型號 | HDR-15-5 | HDR-15-12 | HDR-15-15 | HDR-15-24 | HDR-15-48 | |
輸出 | 直流電壓 | 5V | 12V | 15V | 24V | 48V |
額定電流 | 2.4A | 1.25A | 1A | 0.63A | 0.32A | |
電流範圍 | 0~2.4A | 0~1.25A | 0~1A | 0~0.63A | 0~0.32A | |
額定功率 | 12W | 15W | 15W | 15.2W | 15.4W | |
紋波與噪聲(最大) 備註2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | |
電壓調整範圍 | 4.5~5.5V | 10.8~13.8V | 13.5~18V | 21.6~29V | 43.2~55.2V | |
電壓精度 備註3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
線性調整率 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
負載調整率 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
啟動、上升時間 | 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC(滿載時) | |||||
保持時間(Typ.) | 30ms/230VAC 12ms/115VAC(滿載時) | |||||
輸入 | 電壓範圍 | 85~264VAC(277VAC可用) 120~370VDC(390VDC可用) | ||||
頻率範圍 | 47~63Hz | |||||
效率(Typ.) | 80% | 85% | 85.5% | 86% | 87% | |
交流電流(Typ.) | 0.5A/115VAC 0.25A/230VAC | |||||
浪湧電流(Typ.) | 冷啟動25A/115VAC 45A/230VAC | |||||
保護 | 過負載 | 額定輸出功率的110%~145% | ||||
輸出電壓<50%時為打嗝模式,負載異常條件移除後可自動恢復 輸出電壓在50%~100%時為恆定電流模式,負載異常條件移除後可自動恢復 | ||||||
過電壓 | 5.75~6.75V | 14.2~16.2V | 18.8~22.5V | 30~36V | 56.5~64.8V | |
保護模式:關斷輸出,通過齊納二級管鉗位 | ||||||
環境 | 工作溫度 | -30~+70℃ (請參考"減額曲線") | ||||
工作濕度 | 20 ~ 90% RH,無冷凝 | |||||
儲存溫度、濕度 | -40 ~ +85℃, 10 ~ 95% RH,無冷凝 | |||||
溫度係數 | ±0.03%/℃ (0~50℃) | |||||
耐震動 | 10 ~ 500Hz, 2G 10分鐘/週期, X, Y, Z各60分鐘; 安裝: 符合IEC60068-2-6 | |||||
操作海拔高度 | 2000米(m) | |||||
過電壓等級 | Ⅲ;根據 EN61558, EN50178,EN60664-1, EN62477-1;海拔可高達2000米 | |||||
安規和電磁兼容 | 安全規範 | UL62368-1, UL508, EAC TP TC 004, BSMI CNS14336-1,TUV EN61558-2-16, IEC62368-1認證通過, 設計參考TUV EN62368-1 | ||||
耐壓 | I/P-O/P:4KVAC | |||||
絕緣阻抗 | I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH | |||||
電磁兼容發射 | Parameter | Standard | Test Level / Note | |||
Conducted | EN55032(CISPR32), CNS13438 | Class B | ||||
Radiated | EN55032(CISPR32), CNS13438 | Class B | ||||
Harmonic Current | EN61000-3-2 | Class A | ||||
Voltage Flicker | EN61000-3-3 | ------- | ||||
電磁兼容抗擾度 | EN55024, EN55035, EN61000-6-2, EN61204-3 | |||||
Parameter | Standard | Test Level / Note | ||||
ESD | EN61000-4-2 | Level 3, 8KV air; Level 2, 4KV contact, criteria A | ||||
Radiated Susceptibility | EN61000-4-3 | Level 3, criteria A | ||||
EFT/Burest | EN61000-4-4 | Level 3, criteria A | ||||
Surge | EN61000-4-5 | Level 4,2KV/L-N, criteria A | ||||
Conducted | EN61000-4-6 | Level 3, criteria A | ||||
Magnetic Field | EN61000-4-8 | Level 4, criteria A | ||||
Voltage Dips and interruptions | EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods | ||||
其他 | MTBF | ≥1166K hrs. MIL-HDBK-217F (25℃) | ||||
尺寸 | 17.5*90*54.5mm (W*H*D) | |||||
包裝 | 78g | |||||
備註 | 1. 如未特別說明,所有規格參數均在輸入為230VAC、額定負載、25℃環境溫度下進行量測。 2. 紋波和雜訊測量方法:使用一條12"雙絞線,同時終端要並聯0.1uf和47uf的電容,在20MHZ頻寬下進行量測。 3. 精度:包含設定誤差、線性調整率和負載調整率。 4. 電源被視為是一個獨立的元件,但最終電源仍需結合終端設備進行電磁相容相關確認。有關EMC測試操作指導請參閱“元件電源供應器的EMI測試”。 (在明緯網站http://www.meanwell.cc) 5. 當海拔高度超過2000米(6500英尺)時,無風扇機型環境溫度依每3.5℃/1000m比例下降,有風扇機型環境溫度依每5℃/1000m比例下降。 ※ 產品免責聲明:詳情請參閱 http://www.meanwell.cc/serviceDisclaimer.aspx |